Fence Industry | Decimal O.D. | Pipe wall Thickness | Weight | |||
O.D | Inches | (mm) | Inches | (mm) | lb./ft. | (kg/m) |
1 3/8" | 1.315 | 33.40 | 0.133 | 3.38 | 1.68 | 2.5 |
1 5/8" | 1.660 | 42.16 | 0.140 | 3.56 | 2.27 | 3.38 |
1 7/8" | 1.900 | 48.26 | 0.145 | 3.68 | 2.72 | 4.05 |
2 3/8" | 2.375 | 60.33 | 0.154 | 3.91 | 3.65 | 5.43 |
2 7/8" | 2.875 | 73.03 | 0.203 | 5.16 | 5.80 | 8.62 |
3 1/2" | 3.500 | 88.90 | 0.216 | 5.49 | 7.58 | 11.28 |
4" | 4.000 | 101.60 | 0.226 | 5.74 | 9.12 | 13.56 |
6 5/8" | 6.625 | 168.28 | 0.280 | 7.11 | 18.99 | 28.23 |
8 5/8" | 8.625 | 219.08 | 0.322 | 8.18 | 28.58 | 42.49 |
Intermediate Grade Schedule 80 Pipe- Dimensions and Strength Characteristics
Fence Industry | Decimal O.D. | Pipe wall Thickness | Weight | |||
O.D | Inches | (mm) | Inches | (mm) | lb./ft. | (kg/m) |
6 5/8" | 6.625 | 168.28 | 0.280 | 7.11 | 18.99 | 28.23 |
8 5/8" | 8.625 | 219.08 | 0.322 | 8.18 | 28.58 | 42.49 |
High Strength Grade Schedule 80 Pipe- Dimensions and Strength Characteristics
Fence Industry | Decimal O.D. | Pipe wall Thickness | Weight | |||
O.D | Inches | (mm) | Inches | (mm) | lb./ft. | (kg/m) |
1 5/8" | 1.660 | 42.16 | 0.140 | 3.56 | 2.27 | 3.38 |
1 7/8" | 1.900 | 48.26 | 0.145 | 3.68 | 2.72 | 4.05 |
2 3/8" | 2.375 | 60.33 | 0.154 | 3.91 | 3.65 | 5.43 |
2 7/8" | 2.875 | 73.03 | 0.203 | 5.16 | 5.80 | 8.62 |
3 1/2" | 3.500 | 88.90 | 0.216 | 5.49 | 7.58 | 11.28 |
4" | 4.000 | 101.60 | 0.226 | 5.74 | 9.12 | 13.56 |
HOT-DIPPED GALVANIZED
Pipe shall be coated inside and out by the hot-dip process.
The average weight of zinc coating shall be not less than 1.8
oz/ft2 of surface (inside and outside). A 2.0 oz/ft2 zinc
coating weight is available upon request. A conversion coating
is also applied to the interior and exterior surfaces to
protect them against corrosion and white rust.
Wheatland's zinc coating is virtually lead free.
END FINISH
End finish shall be plain end square cut.
Posts and rails shall be one piece free of welded sections.
TENSILE REQUIREMENTS
Regular Grade - Tensile Strength, min. 48 000 psi
Regular Grade - Yield Strength, min. 30 000 psi
Intermediate Grade* - Tensile Strength, min. 60 000 psi
Intermediate Grade* - Yield Strength, min. 50 000 psi
High Strength Grade - Tensile Strength, min. 85 000 psi
High Strength Grade - Yield Strength, min. 83 000 psi
*Available in 6.625 and 8.625 inch O.D. only
PERMISSIBLE VARIATIONS IN WALL THICKNESS
Minimum wall thickness at any point shall not be more than
12.5% under nominal wall thickness specified.
PERMISSIBLE VARIATIONS IN OUTSIDE DIAMETER
1.900" O.D. and under + 0.016" - 0.031"
2.375" O.D. and over + 1%
Wheatland offers the most extensive size range of any fence
framework manufacturer.
PERMISSIBLE VARIATIONS IN WEIGHT PER FOOT
Pipe shall not vary more than + 10% from the standard
specified.
PRODUCT MARKING
Each length of pipe 1.315" O.D. and larger is
continuously stenciled as follows:
Wheatland, USA, Size, Schedule 40, ASTM F1083, 1.8 oz. or 2.0
oz., Grade, Length, Run #, and Date
Bar Coding is acceptable as a supplementary identification
method.
Wheatland F1083 -08 Schedule 40 Galvanized Pipe meets or
exceeds the following specifications:
American Association of State Highway and Transportation
Officials AASHTO M 181
Federal Specifications RR-F-191/2E and RR-F-191/3E
Army Corps of Engineers UFGS-32 31 00.00 10
Federal Aeronautics Administration AC 150/5370-10C ITEM
F-162
Department of the Navy American Society of Testing and
Materials International ASTM F1083-08
American Society of Testing and Materials International ASTM
F1043 Group IA
U.S. Department of Justice – Federal Bureau of Prisons
American Institute of Architects (AIA) MASTERSPEC